Assay Report
Methods · Standard Curves · QC · Results
Quantify amyloid-beta 1–40 and 1–42 peptides in cerebrospinal fluid and plasma — the two most extensively studied isoforms in Alzheimer's disease pathology research — using electrochemiluminescence (ECL) technology with pre-configured V-PLEX and S-PLEX platforms.
The Aβ42/Aβ40 ratio is a core cerebrospinal fluid biomarker in the AT(N) research framework for Alzheimer's disease, reflecting cerebral amyloid deposition with high concordance to amyloid PET imaging. Plasma Aβ measurements present unique analytical challenges due to their low abundance and matrix interference — our MSD platform's electrochemiluminescence detection overcomes these limitations, delivering the precision required for robust ratio determination in research applications.
Representative performance metrics for MSD-based Aβ40 and Aβ42 quantification in cerebrospinal fluid and plasma research applications.
Note: Values are illustrative and drawn from published literature for informational purposes. Individual study results vary by cohort, matrix, and pre-analytical protocols. These metrics do not constitute performance claims for clinical diagnostic use.
8-point calibration curve with R² ≥ 0.99 for both Aβ40 and Aβ42. Synthetic peptide calibrators traceable to reference preparations. Dilution linearity verified at 1:2, 1:4, and 1:8 in human CSF and plasma matrices.
Intra-plate CV <5% for both Aβ40 and Aβ42 across low, medium, and high QC samples. Inter-plate CV <10%. Three independent QC levels run in duplicate on each plate. Lot-to-lot bridging data available.
The Aβ42/Aβ40 ratio demonstrates superior longitudinal reproducibility compared to individual analyte concentrations, with <3% CV for ratio measurements across replicates. This is particularly valuable for cohort enrichment and longitudinal monitoring studies.
Why precise ratio determination demands robust immunoassay technology — and how electrochemiluminescence delivers.
Plasma Aβ peptides circulate at 10–100 pg/mL — levels that challenge conventional ELISA platforms. More importantly, Aβ42 is prone to aggregation and non-specific binding to collection tubes and assay surfaces, introducing pre-analytical variability that can distort the Aβ42/Aβ40 ratio. Matrix effects from plasma proteins further complicate accurate quantification. The MSD platform addresses each of these challenges through its unique electrochemiluminescence detection architecture.
MSD's high-capacity carbon electrode provides ~10× greater binding surface than polystyrene, minimizing non-specific binding of aggregation-prone Aβ42 and ensuring consistent capture efficiency across the concentration range.
Non-enzymatic SULFO-TAG labels emit light only upon electrical stimulation at the electrode surface. No enzymatic amplification means no substrate depletion, no edge effects, and zero background from sample matrix autofluorescence — critical for low-abundance plasma Aβ detection.
Aβ40 and Aβ42 are measured in the same well using distinct capture antibodies spotted on spatially separated electrode areas. The ratio is computed from within-well signals, eliminating well-to-well variability as a source of ratio imprecision.
ECL's 4–5 log dynamic range accommodates both CSF (ng/mL range) and plasma (pg/mL range) Aβ measurements without dilution adjustment, enabling cross-matrix comparison within a single assay platform.
Relative concordance with amyloid PET in published research cohorts
* NfL is a non-specific marker of axonal injury, not directly reflective of amyloid pathology. Scores reflect amyloid PET concordance based on published head-to-head cohort studies. For research reference only.
Service package, sample requirements, and deliverables.
| Item | Full Service | Kit Only |
|---|---|---|
| Sample Processing | Included | — Self-run |
| Standard Curve | 8-point, each plate | Reagents provided |
| QC Samples | 3 levels, duplicate | — User-prepared |
| Ratio Calculation | Aβ42/Aβ40 ratio reported | — Self-analysis |
| Data Analysis | Full report | — Self-analysis |
| Raw Data | Included | — Instrument-dependent |
For Research Use Only. Not for diagnostic procedures.
Tell us about your study — matrix type, cohort size, longitudinal design. We'll recommend the optimal assay configuration and pre-analytical protocol.
Send your samples on dry ice following our collection guidelines. We provide detailed tube-type and handling recommendations to preserve Aβ integrity.
Receive your complete data package — quantitative report with Aβ42/Aβ40 ratios, QC metrics, and methods documentation formatted for Aβ research publications.
First time measuring Aβ? Ask about our pre-analytical consultation — we'll help you select appropriate collection tubes and develop an aliquot strategy to minimize pre-analytical variability in ratio measurements.
Platform comparison for research applications.
| Feature | MSD V-PLEX | Simoa (Quanterix) | Conventional ELISA | LC-MS/MS |
|---|---|---|---|---|
| Sensitivity (LOD) | 1–5 pg/mL | fg/mL–pg/mL | ~10–50 pg/mL | ~5–10 pg/mL |
| Dynamic Range | 4–5 logs | 4 logs | 2–3 logs | 3–4 logs |
| Simultaneous Aβ40+Aβ42 | Yes — within-well duplex | Requires separate wells | Separate kits required | Yes — multiplexed MS |
| Ratio Precision | Excellent (within-well) | Good (cross-well) | Moderate | Very good |
| Sample Volume | 25 µL | ~100 µL | 100 µL | 250–500 µL |
| Multiplex Capability | Up to 10-plex | Up to 4-plex | Single-plex only | Targeted panels |
| Throughput | 96-well / 70 sec read | ~60 samples/hr | 96-well batch | Low (~20/day) |
| Best Research Fit | Cohort studies, AD trials, multiplex neuro panels | Ultra-low plasma Aβ, single-marker studies | Small pilot studies, CSF only | Isoform-specific, reference method |
For a detailed head-to-head analysis covering all neuro biomarkers, see our Luminex vs MSD vs Simoa: A CRO Guide to Multiplex Cytokine Studies.
Published research supporting Aβ40/Aβ42 and the Aβ42/Aβ40 ratio as biomarkers for Alzheimer's pathology.
References provided for informational and scientific context. For Research Use Only.
No. This Aβ40/Aβ42 assay is validated for research use only (RUO). It is suitable for preclinical studies, cohort research, biomarker discovery, and therapeutic development applications. It is not validated for clinical diagnostic procedures, patient management decisions, or as a standalone screening tool in a clinical setting. All data is reported with the explicit disclaimer that it should not be used as the sole basis for clinical decision-making.
The Aβ42/Aβ40 ratio consistently outperforms Aβ42 concentration alone in published research studies for identifying individuals with cerebral amyloid deposition. The ratio normalizes for inter-individual differences in total Aβ production and pre-analytical factors (e.g., sample dilution, collection tube binding). In the AT(N) research framework, the Aβ42/Aβ40 ratio is the recommended amyloid biomarker metric. Our MSD platform measures both analytes simultaneously in the same well, providing the most robust ratio determination possible.
CSF provides the strongest signal and highest concordance with amyloid PET, with the Aβ42/Aβ40 ratio achieving AUC values of ~0.90 in published cohort studies. Plasma measurements have improved significantly with newer assay platforms and can achieve AUC values of ~0.75–0.85. The choice depends on your research design: CSF for maximum accuracy in smaller studies; plasma for scalable, non-invasive assessment in large cohorts and longitudinal designs. We support both matrices and can advise on the optimal approach for your research objectives.
Aβ42 is prone to non-specific adsorption to polystyrene surfaces — always use polypropylene tubes and plates for collection, aliquot, and storage. For CSF: collect directly into a polypropylene tube, centrifuge at 2,000×g/10 min/4°C, aliquot into polypropylene cryovials, freeze at −80°C. For plasma: collect in EDTA tubes (preferred over heparin or citrate), centrifuge at 1,500×g/10 min/4°C, transfer to polypropylene cryovials, freeze at −80°C. Avoid repeated freeze-thaw cycles. Contact us for a detailed pre-analytical guide.
Yes. Through MSD's U-PLEX custom platform, Aβ40 and Aβ42 can be combined with total Tau, p-Tau181, p-Tau217, p-Tau231, NfL, and GFAP in a single well for comprehensive AT(N) profiling. The within-well duplex measurement of Aβ40 and Aβ42 is preserved in multiplex configurations. Contact us to design a custom panel tailored to your research objectives — we'll help balance sensitivity requirements with multiplexing needs.
Collect CSF or blood per the recommended protocol → centrifuge at specified conditions → transfer to polypropylene cryovials (critical for Aβ) → freeze immediately at −80°C → ship on dry ice via overnight courier. Include a completed sample manifest form. Avoid repeated freeze-thaw cycles. Contact us for a detailed sample collection and shipping guide, including tube-type recommendations and aliquot volume guidance.
Demo Assay Report
Request a representative report to review how assay methods, standard curves, quality-control metrics, and quantitative results are presented.
Online Inquiry
×