Assay Report
Methods · Standard Curves · QC · Results
Quantify endothelial activation (ICAM-1, VCAM-1), acute-phase response (CRP, SAA), and coagulation (Factor VII) using electrochemiluminescence — a single 25 µL sample replaces four separate ELISA measurements while providing 4–5 log dynamic range that CRP ELISA cannot match without serial dilution.
CRP and SAA span 3+ orders of magnitude from healthy baseline (<1 µg/mL) to acute inflammation (>100 µg/mL). In conventional ELISA, this means running every sample at minimum two dilutions with dilution linearity verification. MSD's ECL detection measures the full range in a single 25 µL well — validated against established clinical methods in a 574-participant cross-study (PLoS ONE, 2013). ICAM-1 and VCAM-1 are shed from activated endothelium into circulation, where their soluble forms reflect the total body endothelial activation burden. The 5-Plex adds Factor VII, connecting endothelial status to the extrinsic coagulation cascade — relevant for metabolic syndrome and diabetes research where vascular activation and hypercoagulability co-exist. Each biomarker is measured on its own spatially separated electrode spot within one well, eliminating the cross-assay variability that comes from running these markers across separate ELISA plates, separate dilutions, and separate analytical runs.
| Panel Type | Plex | Biomarkers | Format | Best For |
|---|---|---|---|---|
| Vascular Injury Panel 2 | 4 | CRP, ICAM-1, SAA, VCAM-1 | V-PLEX | Core endothelial activation + systemic inflammation; 1:200 dilution |
| Vascular Injury Combo 1 | 5 | CRP, Factor VII, ICAM-1, SAA, VCAM-1 | U-PLEX | Adds Factor VII for coagulation; 1:2 dilution for higher sensitivity |
| Vascular Injury U-PLEX Custom | 2–10 | Select from vascular injury catalog: add E-Selectin, P-Selectin, Thrombomodulin, MCP-1, IL-8, or other endothelial markers as needed | U-PLEX | Extended vascular panel beyond the standard 4/5-plex; add exploratory markers |
| 54/71-Plex (with Vascular Injury) | 54–71 | CRP, SAA, ICAM-1, VCAM-1 + VEGF-A, PlGF, Tie-2, FGF basic, Eotaxin, IP-10, MCP-1, MDC, TARC, 40+ cytokines | V-PLEX | Vascular injury + angiogenic + cytokine profiling from one 25 µL sample |
The V-PLEX format requires a 1:200 dilution to accommodate CRP µg/mL concentrations alongside ng/mL ICAM-1/VCAM-1. The U-PLEX format offers improved sensitivity (pg/mL range) at a lower 1:2 dilution and adds Factor VII for coagulation context. Both panels measure all analytes from a single 25 µL sample aliquot. For research use only.
C-reactive protein is the most extensively studied systemic inflammation biomarker. Its concentration spans from <1 µg/mL to >100 µg/mL. Conventional hsCRP ELISA tops out at ~10 µg/mL — every sample above that requires dilution and re-run. MSD ECL detects the full range in a single measurement. LOD: 0.04 µg/mL. No hook effect to 5,000 µg/mL.
Serum Amyloid A becomes the predominant HDL protein during acute-phase response, displacing ApoA-I and redirecting HDL to pro-inflammatory functions. Up to 1,000-fold induction. Elevation correlates with HDL dysfunction in metabolic syndrome and cardiovascular disease. LOD: 0.03 µg/mL.
Intercellular Adhesion Molecule-1 (CD54) shed from activated endothelium reflects the total body endothelial activation burden. Binds LFA-1 on all leukocytes — a broad, non-selective endothelial stress marker. Elevated in atherosclerosis, hypertension, and diabetes research. LOD: 0.002 µg/mL.
VCAM-1 (CD106) binds VLA-4 expressed on monocytes and lymphocytes, but not neutrophils — more specific for monocyte-mediated inflammation. VCAM-1 is among the earliest endothelial changes in atherogenesis. ICAM-1 alone = broad activation; ICAM-1 + VCAM-1 = monocyte recruitment signal. LOD: 0.02 µg/mL.
CRP is the most commonly requested biomarker in vascular research — yet it is among the most analytically challenging to measure across the full biological range.
| Item | Full Service | Notes |
|---|---|---|
| Sample Processing | Included | 1:200 dilution with documented dilution factor |
| Standards | 8-point per analyte | Wide-range CRP calibrators covering 0.04–100 µg/mL |
| QC Samples | 3-level, duplicate | Low, medium, high across CRP range |
| Report | Excel + PDF | Concentrations, QC, dilution info, temporal plots |
For Research Use Only. Not for diagnostic procedures.
4-Plex (endothelial + inflammation) or 5-Plex (adds Factor VII for coagulation context).
Serum or EDTA plasma. Standardize AM collection (CRP has diurnal variation). Ship on dry ice.
Endothelial activation + inflammatory marker data with QC and dilution documentation.
van Bussel, B.C.T. et al. (2013) PLoS ONE. 8(3):e58576. "Multiple Inflammatory Biomarker Detection in a Prospective Cohort Study: A Cross-Validation between Well-Established Single-Biomarker Techniques and an Electrochemiluminescence-Based Multi-Array Platform." DOI: 10.1371/journal.pone.0058576 · PMID: 23554903 — 574-participant cross-validation of MSD 4-plex vs clinical CRP/ELISA methods; ICCs of 0.996 (CRP), 0.895 (sICAM-1), 0.858 (sVCAM-1).
Ridker, P.M. et al. (2017) NEJM. 377(12):1119-1131. "Antiinflammatory Therapy with Canakinumab for Atherosclerotic Disease." DOI: 10.1056/NEJMoa1707914 · PMID: 28845751 — CANTOS trial demonstrating CRP-guided anti-inflammatory therapy in CV disease.
Libby, P. et al. (2021) Circulation Research. 128(12):1819-1833. "Inflammation and cardiovascular disease." PMID: 34085822 — Comprehensive review of ICAM-1, VCAM-1, and CRP in CV research.
Gustafson, B. et al. (2007) Diabetologia. 50(11):2340-2348. "Inflammation and endothelial activation in obesity and insulin resistance." PMID: 17823774 — MSD multiplex measurement of CRP, ICAM-1, and VCAM-1 in metabolic disease.
The 574-participant cross-validation study (van Bussel et al., PLoS ONE, 2013) directly addressed this question. After Deming regression to align calibration between methods, the intra-class correlation between MSD ECL and clinical CRP methods was 0.996 — indicating near-perfect agreement across the measured range. The key difference is that MSD measures CRP from <1 µg/mL to >100 µg/mL in a single well, while hsCRP ELISA requires 1:100–1:500 dilution for samples exceeding its ~10 µg/mL linear range. For research studies where CRP may span this full range — cardiovascular cohorts including acute events, post-surgical samples, metabolic syndrome — MSD avoids the reanalysis rate that ELISA imposes. All services are for research use only.
They are complementary, not redundant. ICAM-1 binds LFA-1 on all leukocyte subtypes, making it a broad endothelial activation marker. VCAM-1 binds VLA-4, expressed selectively on monocytes, lymphocytes, and eosinophils but not neutrophils — making it more specific for monocyte-mediated inflammation, which is the initiating step in atherogenesis. In research contexts, elevated ICAM-1 + VCAM-1 suggests active monocyte recruitment beyond general endothelial activation. Several studies have shown that the combination provides better cardiovascular risk discrimination than either marker alone. Measuring both in the same well eliminates cross-assay variability as a confound when comparing their relative elevations. For research use only.
Factor VII is the initiating enzyme of the extrinsic coagulation cascade — it binds tissue factor exposed at sites of endothelial injury and activates Factor X, leading to thrombin generation. Including Factor VII in the 5-Plex bridges endothelial activation status to coagulation potential. This is particularly relevant in metabolic syndrome and diabetes research, where activated endothelium and hypercoagulability co-exist. Elevated Factor VII in these populations correlates with cardiovascular risk independently of CRP. For research use only.
CRP exhibits diurnal variation with a morning peak — standardize collection time across study visits. CRP is stable in serum/plasma for 7 days at 4°C and at least 12 months at −80°C. SAA is similarly stable but more sensitive to repeated freeze-thaw than CRP — single-use aliquots recommended. Hemolyzed samples do not interfere with ECL readout but may indicate collection technique issues. For research use only.
Demo Assay Report
Request a representative report to review how assay methods, standard curves, quality-control metrics, and quantitative results are presented.
Online Inquiry
×